
72
11 Supplement
VEGAFLEX 83 • Modbus and Levelmaster protocol
41838-EN-130314
2
0°C
(32°F)
-40°C
(-104°F)
65°C
(149°F)
80°C
(176°F)
150°C
(302°F)
130°C
(266°F)
3
4
-40°C
(-104°F)
Fig. 39: Ambient temperature - process temperature, standard version
1 Ambient temperature
2 Processtemperature(dependingonthesealmaterial)
3 Maximum permissible temperature - standard
4 Limited temperature range - plastic housing and stainless steel housing, electropolished
Vibration resistance
Ʋ Instrument housing 4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Ʋ Rod probe 1 g with 5 … 200 Hz according EN 60068-2-6 (vibration
at resonance) with rod length 50 cm (19.69 in)
Shock resistance
Ʋ Instrument housing 100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Ʋ Rod probe 25 g, 6 ms according to EN 60068-2-27 (mechanical
shock) with rod length 50 cm (19.69 in)
Electromechanical data - version IP 66/IP 67
Options of the cable entry
Ʋ Cable gland M20 x 1.5
Ʋ Cable diameter (options) 5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)
Ʋ Cable entry ½ NPT
Ʋ Blind plug M20 x 1.5; ½ NPT
Plug options
Ʋ Supply and signal circuit (only with low
voltage)
M12 x 1 plug
Ʋ Indication circuit M12 x 1 plug
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord 0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16)
Comentarios a estos manuales