18
4 Mounting
VEGAFLEX 83 • Modbus and Levelmaster protocol
41838-EN-130314
Fig. 8: Vessel with conical bottom
Plastic vessel/Glass vessel
The guided microwave principle requires a metal surface on the pro-
cess tting. Therefore use in plastic vessels etc. an instrument version
with ange (from DN 50) or place a metal sheet (ø > 200 mm/8 in)
beneath the process tting when screwing it in.
Make sure that the plate has direct contact with the process tting.
When installing rod or cable probes in vessels without metal walls,
e.g. in plastic vessels, the measured value can be inuenced by
strong electromagnetic elds (emitted interference according to
EN 61326: class A). In this case, use a probe with coaxial version.
1 2
Fig. 9: Installation in non-metal vessel
1 Flange
2 Metal sheet
If possible, avoid sockets. Mount the sensor ush with the vessel top.
If this is not possible, use short sockets with small diameter.
Higher sockets or sockets with a bigger diameter can generally be
used. They simply increase the upper blocking distance. Check if this
is relevant for your measurement.
Type of vessel
Socket